Service Hotline: 18664525720

PRODUCTS

Explore durable PP and full-steel laboratory furniture engineered for safety, efficiency, and long-term performance.

START YOUR PROJECT
Dry Chemical Filter
  • Dry Chemical Filter product image

Dry Chemical Filter

Brief Description: PP/PPS dry chemical filter using solid media to adsorb or chemically capture gaseous pollutants. Eight standard models provide airflow capacities up to 62,407 m³/h.

  • Brand: Sciencor
  • Made: China
  • Packing: Plywood Case or Carton
  • Material: PP/PPS
  • Dimension: Customizable
  • Color: Customizable
  • Updated: 2026-08-31
  • Views: 6

Details

Dry Chemical Filter - PP/PPS

The PP/PPS dry chemical filter uses solid filtration media to remove gaseous pollutants from industrial exhaust streams. Pollutants are captured through physical adsorption or fixed by chemical reaction as the gas passes through the media bed.

Working Principle

A dry chemical filter uses solid media to remove gaseous pollutants. As gas passes through the media bed, pollutants are physically adsorbed or fixed by chemical reaction. Purified gas exits the system, and saturated filtration media must be replaced.

Models and Technical Parameters

↔ Swipe horizontally to view all specifications.

ModelDimensions L×W×H (mm)Carbon Volume (m³)DrawersFilter Area (m²)Airflow at 0.5 m/s (m³/h)Airflow at 0.75 m/s (m³/h)Airflow at 1.0 m/s (m³/h)
WHPP-VCT-3K1200×1020×10000.1131.73,1204,6816,241
WHPP-VCT-6K1900×1020×12000.2163.56,2419,36112,481
WHPP-VCT-9K2500×1020×13500.3295.29,36114,04218,722
WHPP-VCT-12K2750×1210×15000.43126.912,48118,72224,963
WHPP-VCT-16K2750×1210×16500.57169.216,64224,96333,284
WHPP-VCT-20K2750×1210×16500.712011.620,80231,20341,605
WHPP-VCT-24K2750×1800×16500.852413.924,96337,44449,926
WHPP-VCT-30K2750×1800×16501.073017.331,20346,80562,407

Technical Requirements

↔ Swipe horizontally to view all specifications.

Inspection ItemUnitRequirementResult
Pressure DropkPa≤ 2.5Pass
AirtightnessWelds, pipe connections, heat exchangers, and other parts of the adsorption unit must be airtight, with no gas leakage.Pass
Operating NoisedB(A)≤ 85Pass
Benzene — Emission Concentrationmg/m³≤ 12Pass
Benzene — Removal Efficiency%≥ 90Pass
Toluene — Emission Concentrationmg/m³≤ 40Pass
Toluene — Removal Efficiency%≥ 90Pass
Xylene — Emission Concentrationmg/m³≤ 70Pass
Xylene — Removal Efficiency%≥ 90Pass