Single-Stage Activated-Carbon Adsorber
  • Single-Stage Activated-Carbon Adsorber product image

Single-Stage Activated-Carbon Adsorber

Brief Description: SUS304/SUS316L single-stage activated-carbon adsorber for industrial VOC treatment. Twenty standard configurations provide airflow capacities up to 62,986 m³/h.

  • Brand: Sciencor
  • Made: China
  • Delivery Time: 20-30 Days
  • Packing: Plywood Case or Carton
  • Material: SUS304 / SUS316L
  • Dimension: Customizable
  • Color: Customizable
  • Updated: 2026-08-31
  • Views: 4

Details

Single-Stage Activated-Carbon Adsorber - Stainless Steel

The SUS304/SUS316L single-stage activated-carbon adsorber is designed for industrial VOC and gaseous-pollutant treatment. Its stainless-steel structure provides high mechanical strength and is suitable for large-airflow applications.

Working Principle

Exhaust gas enters through the inlet and passes through activated-carbon beds, where pollutants are adsorbed. The treated gas then exits through the outlet.

Models and Technical Parameters

↔ Swipe horizontally to view all specifications.

ModelLength L (mm)Width W (mm)Height H (mm)Inlet/Outlet W (mm)Inlet/Outlet H (mm)Centerline Height Above Floor (mm)Airflow at 0.6 m/s (m³/h)Airflow at 1.2 m/s (m³/h)
WH3-5K-1A118085010007007505752,7655,530
WH3-10K-1A11801050135090011007505,18410,368
WH3-15K-1A17301050145090012008007,77615,552
WH3-15K-1B138012501500110012508257,77615,552
WH3-20K-1A213010501650900140090010,36820,736
WH3-20K-1B1730135012001200120080010,10920,218
WH3-20K-1C13801250165011001700105010,36820,736
WH3-25K-1A2330115018001000155097512,83025,661
WH3-25K-1B1930145015001300135087512,70125,402
WH3-25K-1C17301350185012001600100013,47826,957
WH3-30K-1A2330115018001000155097515,16330,326
WH3-30K-1B2130155019001400140090020,73641,472
WH3-35K-1A2780135018001200155097517,69035,381
WH3-35K-1B2330155018001400155097517,49634,992
WH3-40K-1A27801550200014001600100020,41240,824
WH3-40K-1B25301650185015001550100020,73641,472
WH3-50K-1A33801550210014001850112526,24452,488
WH3-50K-1B30801750200016001750107526,43852,877
WH3-60K-1A36801650225015002000120031,10462,208
WH3-60K-1B33801850210017001850112531,49362,986

Technical Requirements

↔ Swipe horizontally to view all specifications.

Inspection ItemUnitRequirementResult
Pressure DropkPa≤ 2.5Pass
AirtightnessWelds and pipe connections of the adsorption unit must be airtight, with no gas leakage.Pass
Operating NoisedB(A)≤ 85Pass
Benzene — Emission Concentrationmg/m³≤ 12Pass
Benzene — Removal Efficiency%≥ 90Pass
Toluene — Emission Concentrationmg/m³≤ 40Pass
Toluene — Removal Efficiency%≥ 90Pass
Xylene — Emission Concentrationmg/m³≤ 70Pass
Xylene — Removal Efficiency%≥ 90Pass

Material Selection Guide

↔ Swipe horizontally to view all specifications.

ComparisonPPStainless Steel
Suitable EnvironmentExhaust gas containing halogens or strong acidsEnvironments requiring explosion-proof certification
Airflow SuitabilitySmall- and medium-scale exhaust-gas treatmentLarge-scale exhaust-gas treatment
Maintenance and Structural CharacteristicsShort maintenance windowNo deformation risk